04Fire Extinguisher Service
Extinguishers serviced and hydro tested.
Servicing, replacement and hydrostatic testing for the portable extinguishers in your building, from the Class K unit at the cook line to the multipurpose units by the doors.
- Service
- 04 / 05
- System coverage
- Fire extinguishers
Fig. 04 — Class K extinguisher and service tag. Not to scale.
04.1Overview
A grease fire needs the right extinguisher.
Cooking-oil and grease fires behave differently from paper or wood fires, and they call for a different extinguisher. Class K units are made for the cook line. Multipurpose units, usually rated ABC, cover the dining room, storage, offices and back-of-house. Most kitchens have both.
An extinguisher can look fine on the wall and still not be ready. Pressure leaks off, pins and seals go missing, hoses crack, and units that were used get hung back up. Servicing catches those problems. Over time, cylinders also need hydrostatic testing, a pressure test of the shell itself, at intervals set by the extinguisher type.
We service extinguishers, replace units that are damaged, expired or fail testing, and handle hydrostatic testing. How often each unit needs service or testing depends on its type and on your local fire authority, and we'll tell you what applies to the units you have.
Extinguisher service at a glanceSpec 04
- Cook line
- Class K units for cooking-oil and grease fires
- Building
- Multipurpose units for dining, storage, offices and back-of-house
- Service
- Servicing, replacement and hydrostatic testing
- Intervals
- Set by extinguisher type and your local fire authority
Placement
Where extinguishers go in a commercial kitchen.
- Class KAt the cook line, for cooking-oil and grease fires
- MultipurposeNear exits, storage, offices and the dining room
A typical layout, for illustration. The type, number and location of units in your building are set by your local fire authority.
04.2Common problems
Signs an extinguisher needs service
Most of these show up in a ten-second look at the unit.
- P–01
Gauge needle out of the green
On stored-pressure units, a needle in the recharge or overcharged zone means the extinguisher may not discharge the way it should.
- P–02
Missing or out-of-date tag
No tag, an unreadable tag or a last service date that's too far back means the unit is due.
- P–03
Used, even briefly
A unit that was discharged, even for a second, needs service or replacement before it goes back on the wall.
- P–04
Due for a hydro test
Cylinders need hydrostatic testing at intervals set by their type. The unit's test date shows when it's coming due.
- P–05
Damaged hose, pin or seal
A cracked hose, a missing pull pin or a broken tamper seal is reason to take a unit out of service until it's checked.
- P–06
Wrong class at the cook line
A multipurpose unit next to the fryers is not a stand-in for a Class K extinguisher made for cooking-oil fires.
04.3What's included
What extinguisher service covers
For the portable extinguishers in your kitchen and the rest of the building.
- 04.01
Servicing
Each unit checked for pressure, condition, pin and seal, hose and nozzle, and serviced as needed, including recharging after use.
- 04.02
Service tags
Every serviced unit tagged with the date and the work done.
- 04.03
Hydrostatic testing
Cylinders pressure-tested at the intervals their type calls for.
- 04.04
Replacement
Damaged, expired and out-of-service units, and units that fail testing, replaced.
- 04.05
Class K at the line
Replacement Class K units for the cook line, and multipurpose units for the rest of the building.
- 04.06
Scheduled around service
Visits set for a time that keeps the work out of the way of your service.
04.4Why it matters
Why it matters
Right class, right place.
- 01
Units charged and intact
Regular service catches lost pressure, missing pins and cracked hoses before anyone has to reach for the extinguisher.
- 02
The right class in the right place
Class K at the cook line, multipurpose units elsewhere.
- 03
A clear service record
Tags on every serviced unit show when it was last maintained, for your records and for inspections.
- 04
Hydro testing handled
Cylinders that come due for hydrostatic testing are tested or replaced instead of staying on the wall.
04.5Process
How a service visit runs
Every unit found, checked, serviced and tagged.
Step 01
Walk the building
We locate every extinguisher, from the cook line to the dining room, storage and offices.
Step 02
Inspect each unit
Pressure, pin and seal, hose and nozzle, physical condition, the existing tag and the hydro test date.
Step 03
Service, test or replace
Units are serviced, hydro tested when due, or replaced. Anything that can't go back in service comes off the wall.
Step 04
Tag
Each serviced unit gets an updated tag showing the date and the work done.
Step 05
Recommend
We point out gaps, like a missing Class K at the line or a unit that's hard to reach.
04.6Questions
Extinguisher questions.
Straight answers to what owners and managers ask us most. Don't see yours? Call (818) 457-7828.
Class K extinguishers are made for fires involving cooking oils and fats, the kind that start at fryers and on the cook line. Kitchens that cook with oil generally keep one near the line, with multipurpose units elsewhere in the building. Your local fire authority sets the specific requirements, and we'll tell you what applies to your kitchen.
Related services
Often paired with extinguishers.
03 — Suppression
Fire Suppression Service
The regular suppression service visit: fusible links and the CO2 cartridge changed out, nozzles cleared of grease, new extinguisher tags.
View service
01 — Installation
Hood Installation
Brand-new hoods ducted all the way to the roof, with a fire suppression system installed on every hood we put in.
View service
Talk to the team
Tag Expired?Hydro Due?
Tell us roughly how many units you have and where. We'll service and tag them, test what's due and replace what can't go back on the wall.